Buy ASME NQA Quality Assurance Requirements For Nuclear Facility Applications from SAI Global. ASME NQA-1– (Revision of ASME NQA-1–). Quality. Assurance. Requirements for. Nuclear Facility. Applications. AN AMERICAN NATIONAL. American Society of Mechanical Engineers (ASME) NQA (95 addenda) and editions. The requirements of these documents shall be complied with .

Author: Zulkimuro Nikozahn
Country: Bosnia & Herzegovina
Language: English (Spanish)
Genre: Politics
Published (Last): 25 May 2015
Pages: 115
PDF File Size: 17.58 Mb
ePub File Size: 2.1 Mb
ISBN: 143-7-93350-897-5
Downloads: 17093
Price: Free* [*Free Regsitration Required]
Uploader: Bagal

The activity shall be described to a level of detail commensurate with the complexity of the activity and the need to assure consistent and acceptable results.

Postoperational Repairs and Modifications. Integrity of the examination shall be maintained by the employer or certifying agency through appropriate confidentiality of files and, where applicable, proctoring of examinations.

Quality — Columbia Energy and Environmental Services

Measuring or test equipment consistently found to be out-ofcalibration shall be repaired or replaced. Control of Purchased Items and Services. These submittals shall include Supplier-recommended disposition e. The original design and associated verification documentation shall be referenced in records of subsequent application of the design.

Guidelines for classifying hydraulic, instrument, and lubrication cleanness are presented in Part III, Subpart 3. The need for, and level of detail in, written procedures or instructions shall be determined based upon complexity of the task, the significance of the item or activity, work environment, and worker proficiency and capability education, training, experience.

Inspection of Soils and Earthwork. The process used to control the current revision and issuance of these documents shall take into account the use of the document and the need for revision in support of operation. A document is not considered to be a quality assurance record until it satisfies the definition of a quality assurance record as defined in this Standard.

Controls shall provide for identification, documentation, evaluation, segregation when practical, and disposition of nonconforming items, and for amse to affected organizations. Control of Supplier-Generated Documents. Kirschenmann, Vice Chair K. The interpretations will be included with the above addenda service. Known problems affecting the standard or previously proved designs 22008 their effects on other features shall be considered.

  ELECTROMECHANICAL DEVICES & COMPONENTS ILLUSTRATED SOURCEBOOK PDF

Software verification methods shall include any one or a combination of design reviews, alternate calculations, and tests performed during computer program development. ASME accepts responsibility for only those interpretations of this document issued in accordance with the established ASME procedures and policies, which precludes the issuance of interpretations by individuals.

If this edition or post edition or addenda is invoked by a procurement document or contract, only Parts I and II should be considered requirements as applicable, unless other specific Parts, Subparts, or Appendices of NQA-1 are specified. Software design requirements shall be identified and documented and their selection reviewed and approved.

Participation by federal agency representative s or person s affiliated with industry is not nqq-1 be interpreted as government or industry endorsement of this code or standard. Cleanness Prior to Installation. The guidance in Part III is not intended to be automatically imposed as supplemental requirements. Critical characteristics to be verified are those that provide reasonable assurance that the item will perform its intended function.

The application of this Part, or portions thereof, shall be invoked by written contracts, policies, procedures, specifications, or other appropriate documents. Supplier nqz-1 and selection and the results therefrom shall be documented and shall include one or more of the following: The program shall provide for the planning and accomplishment of activities affecting quality under suitably controlled conditions.

NQA-1 Nuclear Program FAQ | NSL Analytical

Alternate calculations shall use alternate methods to verify correctness of the original calculations or analyses. Applicable nonmandatory guidance for various subparts is provided in Part III. The results of design verification shall be documented with the identification of the verifier clearly indicated.

Prospective Lead Auditors shall pass an examination that shall evaluate comprehension of and ability to apply the body of knowledge identified above.

Training shall be provided, if needed, to achieve initial proficiency, maintain proficiency, and adapt to changes in technology, methods, or job responsibilities. Class B cleanness should be specified for carbon steel and low-alloy steel surfaces only in special cases because of the difficulty in maintaining such surfaces in that condition after they have been cleaned. The design organization approving the change shall have demonstrated competence in the specific design area of interest and have an adequate understanding of the requirements and intent of the original design.

  AT24C16A DATASHEET PDF

Appropriate verification activities shall be performed for the change.

Testing shall demonstrate adequacy of performance under conditions that simulate the most adverse design conditions. In addition, planning shall consider the following factors, as appropriate, recognizing that this list may neither be complete nor applicable to each phase covered by Part II: Conditions necessary nqx-1 accomplishment of the process shall be included.

In those cases, the unverified portion of nnqa-1 design shall be identified and controlled. The organization upon which this Part, or portions thereof, is invoked shall be responsible for complying with the specified requirements of not only Part I but also Part II.

Washington Subcommittee on Waste Management M. Nqs-1 verification shall be performed in accordance with para. It is the single most important standard for calibration and testing laboratories around the world.

PD635 ASME NQA-1-2008/1A-2009 Quality Assurance

This is the case because these are the versions endorsed by the NRC. Control During Installation Process. These documents subsequently contributed to the development of the nqx-1 CFR Part 21 related commercial grade item definitions. Consent to waive specified hold points shall be recorded prior to continuation of work beyond the designated hold point. Maintenance of Installation Cleanness.